Title
Zaštita od požara i provale primenom netipičnih električnih vodova : doktorska disertacija
Creator
Jevtić, Radoje B. 1973-
Copyright date
2013
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
Other responsibilities
mentor
Blagojević, Milan 1958-
član komisije
Pavlović, Vlastimir
član komisije
Petković, Dejan
član komisije
Radovanović, Radovan 1963-
član komisije
Pešić, Dušica 1961-
Academic Expertise
Društveno-humanističke nauke
University
Univerzitet u Nišu
Faculty
Fakultet zaštite na radu
Group
Katedra za sistemska istraživanja bezbednosti i rizika
Title translated
Fire and burglary protection using atypical electric lines
Publisher
Niš : [R. Jevtić]
Format
PDF/A (141 listova)
description
Umnoženo za odbranu.
Univerzitet u Nišu, Fakultet zaštite na radu, 2013.
Bibliografija: listovi 112-125.
Biografija autora: listovi 126-12.
Summary.
description
Alarm systems
Abstract (en)
Typical or atypical electrical lines in the fire and burglary protection systems were mostly
used for the electric power transmission, while they were less frequently used as the fire and
burglary detectors. For the successful use of typical and atypical electrical lines in fire and
burglary protection systems, it is necessary to know lot of parameters, such as specific resistance,
thermal conductivity, linear capacity, characteristic impedance etc., as well as change
mechanism and parameters dependence due to some determinate disturbance.
Using typical and atypical power lines can solve the problem of early detection and
determination of disorders caused by a fire or burglary.
This PhD thesis consists of eight chapters.
The first chapter is an introductory part where the basic terms of the fire and burglary
protection were presented. The modern solutions related to the use of typical and atypical power
lines in the fire protection and burglary protection systems were presented.
The second chapter contains the basic theoretical principles, techniques and methods in the
experiments that were applied, and that could be applied in future research and experiments.
The third chapter presents results based of experiments .The results represent solutions
related to right time reaction in the fire and burglary protection systems, as well as the
determination of the location on typical and atypical power lines where disorders occurred. The
results are designed to have a theoretical assumption, experimental part, results comparison, and
some of them simulation in the appropriate software.
The analyze results of typical and atypical electrical lines in the fire and burglary
protection systems are presented in fourth chapter. The main reasons and advantages for which
the use of these lines in the fire and burglary protection systems can be justified were given.
The fifth chapter is conclusion where the realized results of the realization procedure of the
given goals of this paper were presented.
The sixth chapter consists of a literature used review: books, journals, papers from journals
and conference proceedings, papers from conferences and symposiums, web sites, standards,
rules and regulations.
The brief biography of candidate is presented in the seventh chapter.
The author’s statements about the authorship; identity of printed and electronic version of
doctoral dissertation and the terms of the use are presented in the eighth chapter.
Authors Key words
Zaštita od požara, Zaštita od provale
Authors Key words
atypical electrical line, coaxial cable, measurement, experiment, simulation
Subject
614.83/.84
Type
Elektronska teza
Abstract (en)
Typical or atypical electrical lines in the fire and burglary protection systems were mostly
used for the electric power transmission, while they were less frequently used as the fire and
burglary detectors. For the successful use of typical and atypical electrical lines in fire and
burglary protection systems, it is necessary to know lot of parameters, such as specific resistance,
thermal conductivity, linear capacity, characteristic impedance etc., as well as change
mechanism and parameters dependence due to some determinate disturbance.
Using typical and atypical power lines can solve the problem of early detection and
determination of disorders caused by a fire or burglary.
This PhD thesis consists of eight chapters.
The first chapter is an introductory part where the basic terms of the fire and burglary
protection were presented. The modern solutions related to the use of typical and atypical power
lines in the fire protection and burglary protection systems were presented.
The second chapter contains the basic theoretical principles, techniques and methods in the
experiments that were applied, and that could be applied in future research and experiments.
The third chapter presents results based of experiments .The results represent solutions
related to right time reaction in the fire and burglary protection systems, as well as the
determination of the location on typical and atypical power lines where disorders occurred. The
results are designed to have a theoretical assumption, experimental part, results comparison, and
some of them simulation in the appropriate software.
The analyze results of typical and atypical electrical lines in the fire and burglary
protection systems are presented in fourth chapter. The main reasons and advantages for which
the use of these lines in the fire and burglary protection systems can be justified were given.
The fifth chapter is conclusion where the realized results of the realization procedure of the
given goals of this paper were presented.
The sixth chapter consists of a literature used review: books, journals, papers from journals
and conference proceedings, papers from conferences and symposiums, web sites, standards,
rules and regulations.
The brief biography of candidate is presented in the seventh chapter.
The author’s statements about the authorship; identity of printed and electronic version of
doctoral dissertation and the terms of the use are presented in the eighth chapter.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.